    Evaluating optimum tilt angle for PV modules using solar radiation models in Wuhan, China

    한글로보기

    https://www.riss.kr/link?id=A100656240

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Four models are used to estimate the hourly solar radiation on 15 pieces of different tilted photovoltaic (PV) modules in Wuhan, China based on power and solar radiation data during a whole year. The optimum tilt angle (OTA) in Wuhan for yearly and semi-yearly adjustment was determined. Then it was determined that the best mode is the tilt angle of PV module adjusted every half a year. In semi-yearly adjustment, OTA in semi-year of winter and summer is found as 45°, 15°, respectively. Experimental results verify the theoretical calculated values of the OTA with high precision. Energy radio (ER) reveals PV modules with adjustment of tilt angle twice a year has a capability to improve nearly 7% in comparison with fixed type. The best model was chosen based on test results from statistical indicators. The statistical results demonstrate that among the studied models, Liu&Jordan model is the most accurate.
    번역하기

    Four models are used to estimate the hourly solar radiation on 15 pieces of different tilted photovoltaic (PV) modules in Wuhan, China based on power and solar radiation data during a whole year. The optimum tilt angle (OTA) in Wuhan for yearly and se...

    Four models are used to estimate the hourly solar radiation on 15 pieces of different tilted photovoltaic (PV) modules in Wuhan, China based on power and solar radiation data during a whole year. The optimum tilt angle (OTA) in Wuhan for yearly and semi-yearly adjustment was determined. Then it was determined that the best mode is the tilt angle of PV module adjusted every half a year. In semi-yearly adjustment, OTA in semi-year of winter and summer is found as 45°, 15°, respectively. Experimental results verify the theoretical calculated values of the OTA with high precision. Energy radio (ER) reveals PV modules with adjustment of tilt angle twice a year has a capability to improve nearly 7% in comparison with fixed type. The best model was chosen based on test results from statistical indicators. The statistical results demonstrate that among the studied models, Liu&Jordan model is the most accurate.

    더보기

    목차 (Table of Contents)

    • Abstract
    • I. INTRODUCTION
    • II. THEORY AND MODELS
    • III. EVALUATION OF OPTIMUM TILT ANGLE
    • IV. EXPERIMENTAL RESULTS AND DISCUSSION
    • Abstract
    • I. INTRODUCTION
    • II. THEORY AND MODELS
    • III. EVALUATION OF OPTIMUM TILT ANGLE
    • IV. EXPERIMENTAL RESULTS AND DISCUSSION
    • V. CONCLUSIONS
    • REFERENCES
    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼